publications.
The publications shown here refer only to previously published journal articles. A complete list of publications including talks, conference papers, pre-prints and awards can be requested.
Google Scholar Profile
View complete metrics and citations
2026
- OptiGAN for Crystal Arrays: Physics-Informed Generative Modeling of Optical Photon Transport in PET Detector ArraysStephan Naunheim, Brandon Pardi , Guneet Mummaneni , and 2 more authorsPhysics in Medicine & Biology, 2026
Monte Carlo simulations of optical photon transport are computationally prohibitive for large-scale optical systems including detector arrays and PET systems, restricting their practical use to single-crystal studies. This work presents an enhanced conditional generative adversarial network (optiGAN) capable of replacing optical simulations at the crystal array level, extending our previous single-crystal approach to a 3\texttimes 3 BGO detector array. We introduce Fourier feature encoding and a learnable latent mapping network as the modifications enabling stable training on the array geometry, together with a physics-informed loss term enforcing the unit-sphere state space S2 of the generated propagation directions as a soft constraint. Training data requirements are reduced eight-fold by exploiting the array’s symmetry. The model is evaluated in three studies: a full array evaluation, a high-resolution study probing generalization, and a pencil beam irradiation study assessing practical applicability. Performance is benchmarked against GATE10/Geant4 ground truth, using the fluctuations between independent Monte Carlo runs. The enhanced optiGAN achieves similarity values within 3σ-agreement of the Monte Carlo baseline across all evaluation conditions. An ablation and attribution analysis shows that the physics-informed loss term reduces low-SSIM bin fractions by a factor of 3.6 on the outer crystals, with a localized trade-off at the central crystal, yielding a net 48% reduction over the full array. The model transitions from electron-emission training data to realistic γ-photon interactions, producing flood maps that reproduce experimental patterns including photopeak clusters and inter-crystal scatter lines. This proof-of-concept demonstrates that a physics-informed generative model can simulate optical photon transport in segmented scintillator arrays at a training and inference cost accessible on a single workstation GPU. This provides a foundation for future models capable of generalizing across diverse array configurations.
2025
- Rethinking timing residuals: advancing PET detectors with explicit TOF correctionsStephan Naunheim, Luis Paiva , Vanessa Nadig , and 4 more authorsFrontiers in Physics, Apr 2025
PET is a functional imaging method that can visualize metabolic processes and relies on the coincidence detection of emitted annihilation quanta. From the signals recorded by coincident detectors, TOF information can be derived, usually represented as the difference in detection timestamps. Incorporating the TOF information into the reconstruction can enhance the image’s SNR. Typically, PET detectors are assessed based on the coincidence time resolution (CTR) they can achieve. However, the detection process is affected by factors that degrade the timing performance of PET detectors. Research on timing calibrations develops and evaluates concepts aimed at mitigating these degradations to restore the unaffected timing information. While many calibration methods rely on analytical approaches, machine learning techniques have recently gained interest due to their flexibility. We developed a residual physics-based calibration approach, which combines prior domain knowledge with the flexibility and power of machine learning models. This concept revolves around an initial analytical calibration step addressing first-order skews. In the subsequent step, any deviation from a defined expectation is regarded as a residual effect, which we leverage to train machine learning models to eliminate higher-order skews. The main advantage of this idea is that the experimenter can guide the learning process through the definition of the timing residuals. In earlier studies, we developed models that directly predicted the expected time difference, which offered corrections only implicitly (implicit correction models). In this study, we introduce a new definition for timing residuals, enabling us to train models that directly predict correction values (explicit correction models). We demonstrate that the explicit correction approach allows for a massive simplification of the data acquisition procedure, offers exceptionally high linearity, and provides corrections able to improve the timing performance from (371 ± 6) ps to (281 ± 5) ps for coincidences from 430 keV to 590 keV. Furthermore, the novel definition makes it possible to exponentially reduce the models in size, making it suitable for applications with high data throughput, such as PET scanners. All experiments are performed with two detector stacks comprised of 4×4 LYSO:Ce,Ca crystals (each 3.8 mm × 3.8 mm x 20 mm), which are coupled to 4 × 4 Broadcom NUV-MT SiPMs and digitized with the TOFPET2 ASIC.
- 3D in-system calibration method for PET detectorsYannick Kuhl , Florian Mueller , Julian Thull , and 3 more authorsMedical Physics, Apr 2025
Background Light-sharing detector designs for positron emission tomography (PET) systems have sparked interest in the scientific community. Particularly, (semi-)monoliths show generally good performance characteristics regarding 2D positioning, energy-, and timing resolution, as well as readout area. This is combined with intrinsic depth-of-interaction (DOI) capability to ensure a homogeneous spatial resolution across the entire field of view (FoV). However, complex positioning calibration processes limit their use in PET systems, especially in large-scale clinical systems. Purpose This work proposes a new 3D positioning in-system calibration method for fast and convenient (re-)calibration and quality control of assembled PET scanners. The method targets all kinds of PET detectors that achieve the best performance with individual calibration, including complex segmented detector designs. The in-system calibration method is evaluated and empirically compared to a state-of-the-art fan-beam calibration for a small-diameter proof of concept (PoC) scanner. A simulation study evaluates the method’s applicability to different scanner geometries. Methods A PoC scanner geometry of 120 mm inner diameter and 150 mm axial extent was set up consisting of five identical finely segmented slab detectors (one detector under test and four collimation detectors). A 22Na point source was moved in a circular path inside the FoV. Utilizing virtual collimation and by selecting gamma rays incident approximately perpendicular to the detector normal of the detector under test, training data was created for the training of a 2D positioning model with the machine-learning technique gradient tree boosting (GTB). Data with oblique ray angles was acquired in the same measurement for subsequent angular DOI calibration. For this, a 2D position estimate in the detector under test was calculated first. On this basis, the DOI label was calculated geometrically from the ray path within the detector to finally establish up to 3D training data. Results With a mean absolute error (MAE) of 0.8 and 1.19 mm full-width at half maximum (FWHM) along the planar-monolithic slab dimension, the in-system methods performed similarly within 1% to the fan-beam collimator results. The DOI performance was at ∼90% with 1.13 mm MAE and 2.47 mm FWHM to the fan-beam collimator. Analytical calculations suggest an improved performance for larger scanner geometries. Conclusion The functionality of the 3D in-system positioning calibration method was successfully demonstrated with the measurements within a PoC scanner configuration with similar positioning performance as the bench-top fan-beam setup. The in-system calibration method can be used to calibrate and test fully assembled PET systems to enable more complex light-sharing detector architectures in, for example, large PET systems with many detectors. The acquired data can further be used for more complex energy and time calibrations.
- ASICs in PET: what we have and what we needVanessa Nadig , Stefan Gundacker , Katrin Herweg , and 4 more authorsEJNMMI Physics, Feb 2025
Designing positron emission tomography (PET) scanners involves several significant challenges. These include the precise measurement of the time of arrival of signals, accurate integration of the pulse shape, maintaining low power consumption, and supporting the readout of thousands of channels. To address these challenges, researchers and engineers frequently develop application-specific integrated circuits (ASICs), which are custom-designed readout electronics optimized for specific tasks. As a result, a wide range of ASIC solutions has emerged in PET applications. However, there is currently no comprehensive or standardized comparison of these ASIC designs across the field.
2024
- Holistic evaluation of a machine learning-based timing calibration for PET detectors under varying data sparsityStephan Naunheim, Florian Mueller , Vanessa Nadig , and 8 more authorsPhysics in Medicine & Biology, Feb 2024
Objective. Modern PET scanners offer precise TOF information, improving the SNR of the reconstructed images. Timing calibrations are performed to reduce the worsening effects of the system components and provide valuable TOF information. Traditional calibration procedures often provide static or linear corrections, with the drawback that higher-order skews or event-to-event corrections are not addressed. Novel research demonstrated significant improvements in the reachable timing resolutions when combining conventional calibration approaches with machine learning, with the disadvantage of extensive calibration times infeasible for a clinical application. In this work, we made the first steps towards an in-system application and analyzed the effects of varying data sparsity on a machine learning timing calibration, aiming to accelerate the calibration time. Furthermore, we demonstrated the versatility of our calibration concept by applying the procedure for the first time to analog readout technology. Approach. We modified experimentally acquired calibration data used for training regarding their statistical and spatial sparsity, mimicking reduced measurement time and variability of the training data. Trained models were tested on unseen test data, characterized by fine spatial sampling and rich statistics. In total, 80 decision tree models with the same hyperparameter settings, were trained and holistically evaluated regarding data scientific, physics-based, and PET-based quality criteria. Main results. The calibration procedure can be heavily reduced from several days to some minutes without sacrificing quality and still significantly improving the timing resolution from to compared to conventionally used analytical calibration methods.Significance. This work serves as the first step in making the developed machine learning-based calibration suitable for an in-system application to profit from the method’s capabilities on the system level. Furthermore, this work demonstrates the functionality of the methodology on detectors using analog readout technology. The proposed holistic evaluation criteria here serve as a guideline for future evaluations of machine learning-based calibration approaches.
- A finely segmented semi-monolithic detector tailored for high-resolution PETYannick Kuhl , Florian Mueller , Stephan Naunheim, and 7 more authorsMedical Physics, Feb 2024
Background Preclinical research and organ-dedicated applications use and require high (spatial-)resolution positron emission tomography (PET) detectors to visualize small structures (early) and understand biological processes at a finer level of detail. Researchers seeking to improve detector and image spatial resolution have explored various detector designs. Current commercial high-resolution systems often employ finely pixelated or monolithic scintillators, each with its limitations. Purpose We present a semi-monolithic detector, tailored for high-resolution PET applications with a spatial resolution in the range of 1 mm or better, merging concepts of monolithic and pixelated crystals. The detector features LYSO slabs measuring (24 × 10 × 1) mm3, coupled to a 12 × 12 readout channel photosensor with 4 mm pitch. The slabs are grouped in two arrays of 44 slabs each to achieve a higher optical photon density despite the fine segmentation. Methods We employ a fan beam collimator for fast calibration to train machine-learning-based positioning models for all three dimensions, including slab identification and depth-of-interaction (DOI), utilizing gradient tree boosting (GTB). The data for all dimensions was acquired in less than 2 h. Energy calculation was based on a position-dependent energy calibration. Using an analytical timing calibration, time skews were corrected for coincidence timing resolution (CTR) estimation. Results Leveraging machine-learning-based calibration in all three dimensions, we achieved high detector spatial resolution: down to 1.18 mm full width at half maximum (FWHM) detector spatial resolution and 0.75 mm mean absolute error (MAE) in the planar-monolithic direction, and 2.14 mm FWHM and 1.03 mm MAE for DOI at an energy window of (435–585) keV. Correct slab interaction identification in planar-segmented direction exceeded 80%, alongside an energy resolution of 12.7% and a CTR of 450 ps FWHM. Conclusions The introduced finely segmented, high-resolution slab detector demonstrates appealing performance characteristics suitable for high-resolution PET applications. The current benchtop-based detector calibration routine allows these detectors to be used in PET systems.
2023
- Improving the Timing Resolution of Positron Emission Tomography Detectors Using Boosted Learning—A Residual Physics ApproachStephan Naunheim, Yannick Kuhl , David Schug , and 2 more authorsIEEE Transactions on Neural Networks and Learning Systems, Feb 2023
Artificial intelligence (AI) is entering medical imaging, mainly enhancing image reconstruction. Nevertheless, improvements throughout the entire processing, from signal detection to computation, potentially offer significant benefits. This work presents a novel and versatile approach to detector optimization using machine learning (ML) and residual physics. We apply the concept to positron emission tomography (PET), intending to improve the coincidence time resolution (CTR). PET visualizes metabolic processes in the body by detecting photons with scintillation detectors. Improved CTR performance offers the advantage of reducing radioactive dose exposure for patients. Modern PET detectors with sophisticated concepts and read-out topologies represent complex physical and electronic systems requiring dedicated calibration techniques. Traditional methods primarily depend on analytical formulations successfully describing the main detector characteristics. However, when accounting for higher-order effects, additional complexities arise matching theoretical models to experimental reality. Our work addresses this challenge by combining traditional calibration with AI and residual physics, presenting a highly promising approach. We present a residual physics-based strategy using gradient tree boosting and physics-guided data generation. The explainable AI framework SHapley Additive exPlanations (SHAPs) was used to identify known physical effects with learned patterns. In addition, the models were tested against basic physical laws. We were able to improve the CTR significantly (more than 20%) for clinically relevant detectors of 19 mm height, reaching CTRs of 185 ps (450–550 keV).
- Angular Irradiation Methods for DOI Calibration of Light-Sharing Detectors - A perspective for PET In-System CalibrationYannick Kuhl , Stephan Naunheim, David Schug , and 2 more authorsIEEE Transactions on Radiation and Plasma Medical Sciences, Feb 2023
Typical positron emission tomography (PET) detectors consist of one-layer segmented scintillators coupled to silicon photomultipliers (SiPMs). Light-sharing detectors, e.g., semi-monoliths, additionally provide depth-of-interaction (DOI) estimation, performing best when calibrated individually. To establish those designs in large PET systems, scalable (re-)calibration methods are needed, possibly transferable to assembled systems. Here, two DOI calibration methods, potentially allowing in-system calibration, are evaluated and compared with an established calibration scheme. Both methods are based on angular detector irradiation using a fan-beam slit collimator and gradient tree boosting (GTB) for 3-Dimensional (3D) position estimation. The positioning performance was assessed for irradiation angles between 0∘ (lateral) and 90∘ (detector normal). With lateral irradiation, a unique DOI position is given, whereas with angular irradiation a gamma-individual reference position must be retrieved. The first method employs one angular beam and calculates DOI from the beam path and planar position estimation. The second method uses two intersecting beams. The intersection defines DOI for gamma interactions that are spatially localized there. Those gamma photons are identified by light distribution comparison using a nearest-neighbor routine. The methods were evaluated on a semimonolithic LYSO slab detector (32×3.9×19 mm slabs). Both methods performed similarly to the benchmark lateral irradiation within 1 %, and 6 %, respectively, for shallow irradiation angles up to 45∘.
2022
- Analysis of a convex time skew calibration for light sharing-based PET detectorsStephan Naunheim, Yannick Kuhl , Torsten Solf , and 3 more authorsPhysics in Medicine & Biology, Feb 2022
Objective. Positron emission tomography (PET) detectors providing attractive coincidence time resolutions (CTRs) offer time-of-flight information, resulting in an improved signal-to-noise ratio of the PET image. In applications with photosensor arrays that employ timestampers for individual channels, timestamps typically are not time synchronized, introducing time skews due to different signal pathways. The scintillator topology and transportation of the scintillation light might provoke further skews. If not accounted for these effects, the achievable CTR deteriorates. We studied a convex timing calibration based on a matrix equation. In this work, we extended the calibration concept to arbitrary structures targeting different aspects of the time skews and focusing on optimizing the CTR performance for detector characterization. The radiation source distribution, the stability of the estimations, and the energy dependence of calibration data are subject to the analysis. Approach. A coincidence setup, equipped with a semi-monolithic detector comprising 8 LYSO slabs, each 3.9mm×31.9mm×19.0mm, and a one-to-one coupled detector with 8×8 LYSO segments of 3.9mm×3.9mm×19.0mm volume is used. Both scintillators utilize a dSiPM (DPC3200-22-44, Philips Digital Photon Counting) operated in first photon trigger. The calibration was also conducted with solely one-to-one coupled detectors and extrapolated for a slab-only setup. Main results. All analyzed hyperparameters show a strong influence on the calibration. Using multiple radiation positions improved the skew estimation. The statistical significance of the calibration dataset and the utilized energy window was of great importance. Compared to a one-to-one coupled detector pair achieving CTRs of 224 ps the slab detector configuration reached CTRs down to 222 ps, demonstrating that slabs can compete with a clinically used segmented detector design. Significance. This is the first work that systematically studies the influence of hyperparameters on skew estimation and proposes an extension to arbitrary calibration structures (e.g., scintillator volumes) of a known calibration technique.
- A semi-monolithic detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-capabilities for clinical PET applicationsFlorian Mueller , Stephan Naunheim, Yannick Kuhl , and 3 more authorsMedical Physics, Feb 2022
Background Current clinical positron emission tomography (PET) systems utilize detectors where the scintillator typically contains single elements of 3–6-mm width and about 20-mm height. While providing good time-of-flight performance, this design limits the spatial resolution and causes radial astigmatism as the depth-of-interaction (DOI) remains unknown. Purpose We propose an alternative, aiming to combine the advantages of current detectors with the DOI capabilities shown for monolithic concepts, based on semi-monolithic scintillators (slabs). Here, the optical photons spread along one dimension enabling DOI-encoding with a still small readout area beneficial for timing performance. Methods An array of eight monolithic LYSO slabs of dimensions 3.9 × 32 × 19 mm3 was read out by a 64-channel photosensor containing digital SiPMs (DPC3200-22-44, Philips Digital Photon Counting). The position estimation in the detector’s monolithic and DOI direction was based on a calibration with a fan beam collimator and the machine learning technique gradient tree boosting (GTB). Results We achieved a positioning performance in terms of mean absolute error (MAE) of 1.44 mm for the monolithic direction and 2.12 mm for DOI considering a wide energy window of 300–700 keV. The energy resolution was determined to be 11.3%, applying a positional-dependent energy calibration. We established both an analytical and machine-learning-based timing calibration approach and applied them for a first-photon trigger. The analytical timing calibration corrects for electronic and optical time skews leading to 240 ps coincidence resolving time (CRT) for a pair of slab-detectors. The CRT was significantly improved by utilizing GTB to predict the time difference based on specific training data and applied on top of the analytical calibration. We achieved 209 ps for the wide energy window and 198 ps for a narrow selection around the photopeak (411–561 keV). To maintain the detector’s sensitivity, no filters were applied to the data during processing. Conclusion Overall, the semi-monolithic detector provides attractive performance characteristics. Especially, a good CRT can be achieved while introducing DOI capabilities to the detector, making the concept suitable for clinical PET scanners.